Meridian America Link/Customer Controlled Routing User Manual
Page 177

Chapter 9: Meridian Link/CCR interface cabling 159
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Table 46
NT1R03AA 50-pin four-port cable pinout (IPE Module)
From
DB-50
To
DB-25
Port
Signal
name
From
DB-50
To
DB-25
Port
Signal
name
1
7
1
GND1
26
8
1
DCD1
2
2
1
TXD1
27
3
1
RXD1
3
4
1
RTS1
28
5
1
CTS1
4
6
1
DSR1
29
20
1
DTR1
5
7
3
GND3
30
8
3
DCD3
6
2
3
TXD3
31
3
3
RXD3
7
4
3
RTS3
32
5
3
CTS3
8
6
3
DSR3
33
20
3
DTR3
9
7
5
GND5
34
8
5
DCD5
10
2
5
TXD5
35
3
5
RXD5
11
4
5
RTS5
36
5
5
CTS5
12
6
5
DSR5
37
20
5
DTR5
13
15
5
TXCI5
38
17
5
RXCI5
14
22
5
RI5
39
24
5
TXCO5
15
7
7
GND7
40
8
7
DCD7
16
2
7
TXD7
41
3
7
RXD7
17
4
7
RTS7
42
5
7
CTS7
18
6
7
DSR7
43
20
7
DTR7
19
15
7
TXCI7
44
17
7
RXCI7
20
22
7
RI7
45
24
7
TXCO7
From
DB-50
To
DB-15
Port
Signal
name
From
DB-50
To
DB-15
Port
Signal
name
21
2
Ethernet
C+
46
9
Ethernet
C-
22
3
Ethernet
T+
47
10
Ethernet
T-
23
5
Ethernet
R+
48
12
Ethernet
R-
24
6
Ethernet
SG
49
13
Ethernet
+12VF
25
FGND
FGND
50
FGND
FGND
Note: Pins 21Ð24 and 46Ð49 of the NT1R03AA cable connect to pins 2, 3, 5, 6, 9, 10, 12,
and 13 of the DB-15 Ethernet connector.