192 Chapter 9: Meridian Link/CCR interface cabling
553-3202-210 Standard October 1998
NT8D11 backplane cable reroutingÑto accommodate the IPE
Module in PE slots 0Ð3
With the cables located as shown in Table 64, use the following procedure
to reroute the backplane cables. Note that an IPE Module located in slots
0Ð3 uses I/O connector ports A and D.
1
Leave cable A in slot position L0.
2
Remove cable C from the backplane and connect cable ends C-1,
C-2, and C-3 to slot positions L3-1, L3-2, and L3-3.
3
Move the C connector on the I/O panel to position D. Now the cable
designation is changed from C to D.
!
CAUTION
Risk of hardware damage
With this cable rerouting, the IPE Module can be used
only in PE slots 0Ð3. Also, when the IPE Module is not
in PE slots 0Ð3, PE slot 2 should not be used at all.