Chapter 14: Software installation, upgrade, and update procedures 413
Meridian Link Release 5C/CCR Release 3C Installation and Upgrade Guide
Procedure 5: Load the operating system tape on an
Application Module with an MVME147 card
This procedure assumes that you have backed up all files and have powered
down the Application Module (Procedure 4).
ATTENTION
Do not press the [Backspace] or [Delete] key when the operating
system is not installed, or you may drop out of the procedure into a
previous menu or out of the installation procedure altogether. Use #
(hold the [Shift] key and press 3) to backspace.
If you drop out of the procedure (into the Т#У prompt), start the
reinstallation procedure from the beginning.
Note: If you intend to activate CCR and use terminals or printers,
ensure that the MVME332XT or MVME332XTS card is installed
before you start this procedure.
If you are sure that your MVME147 card has been configured (for example,
if you are upgrading software on a working system), skip steps 3Ð13 and go
directly from step 2 to step 14.
1
Set the appropriate breaker on the MPDU to the ON position.
The following messages appear.
Figure 143
System restart messages (MVME147 card)
Copyright Motorola Inc. 1989,1990,1991, All Rights Reserved
VME147 Monitor/Debugger Release 2.42 - 8/1/91
CPU running at 25 MHz
FPC passed test
MMU passed test
COLD Start
Onboard RAM start = $00000000, stop = $007FFFFF
No offboard RAM detected