beautypg.com

Focus adjustment for the manual focusing type, Focus adjustment for, The manual focusing type -14 – KEYENCE IV Series User Manual

Page 82: Focus adjustment for the

background image

4-14

- IV Series User's Manual (Monitor) -

Focus adjustment for the manual

focusing type

1

Start the Settings Navigator.

“Starting the Settings Navigator” (Page 4-3)

2

Display the main screen for the Image

Optimization.

“Settings Navigator screen and operation flow”

(Page 4-4)

3

Tap the [Focus Adjustment] button.

The Settings Navigator guide opens.

4

Tap the [OK] button.

The focus indicator will be displayed on the
monitor.

5

Image the target.

If the target is to be imaged using an external
trigger, input the external trigger.
If an external trigger cannot be input, tap the

button (Page 4-7) to image the target by

inputting an internal trigger temporarily. Imaging
by inputting an internal trigger finishes by the

button.

6

Turn the focus adjustment screw of

the sensor with the attached flathead

screwdriver, and adjust the focus until the

focus value reaches the peak mark.

Peak mark

Bar gauge

The peak mark is displayed on the position
where the focus is at the maximum. Turn the
focus adjustment screw to make the bar gauge
on the peak mark position.
By tapping the [Clear peak] button, the peak
mark will be hidden, and the current focusing
value will be updated as a maximum value.

When the focus cannot be adjusted by

watching the focus indicator on the monitor,

you can check with the blinking cycle of the

STATUS and OUT of the indicator light.

y

Quickly blinks ...... Focused.

y

Slowly blinks .......

Not focused. Adjust to the

most blinking position.

STATUS indicator light

OUT indicator light

Trigger Options Auto Brightness Adjustment

Focus Adjustment

Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)