Read this manual thoroughly before using the product.
Keep this manual readily available for future reference.
■
Safety precautions
•
Avoid running the PZ-G cable along with power and high voltage lines, as this may cause
interference and/or permanent damage.
•
When using a commercially available switching regulator, ground its chassis grounding and
earth grounding terminals.
•
Do not use in locations where direct ambient light or external light directly shines on the light
receiving surface.
•
With retro-reflective type sensors, when detecting highly reflective materials (such as mirrored
surfaces), stabilization may be difficult. To correct this, change the angle of the sensor head, or
adjust the sensitivity.
•
Avoid using power which exceeds the specifications for ripple (10% max)
•
Avoid using excess force when rotating the operation mode selector switch (Light-on, Dark-on)
and the sensitivity adjustment trimmer.
•
This product is just intended to detect the object(s). Do not use this product for the purpose to
protect a human body or a part of human body.
•
This product is not intended for use as explosion-proof product. Do not use this product in a
hazardous location and/or potentially explosive atmosphere.
■
UL Certificate
This product is an UL/C-UL Listed product.
•
UL File No. E301717
•
Category NRKH,NRKH7
•
Enclosure Type 1 (Based on UL50)
Be sure to consider the following specifications when using this product as an UL/C-UL Listed
Product.
•
Use the power supply with Class 2 output defined in NFPA70 (NEC: National Electrical Code).
•
Power supply/ Control input/ Control output circuits shall be connected to a single Class 2
source only.
•
Use with the over current protection device which is rated 30V or more and not more than 1A.
● PZ-G5xN/G5xP
● PZ-G5xB
● PZ-G4xN/G4xP/G10xN/
● PZ-G4xB/G10xB/G6xB
G10xP/G6xN/G6xP
* The model name with "C" (PZ-GxxCx) is the connector type, and the model name with "E" (PZ-
GxxEx) is the pigtail quick disconnect type.
■
Side Mounting
(Prepare M3 screws)
Tightening torque: 0.5 N·m or less
Tightening torque: 0.5 N·m or less
■
Mounting with the M18 nut (includes nut type)
The M18 nut is also available separately as OP-84225 (2 pcs. supplied).
Tightening torque:1.0 N·m or less
•
Mount the M18 nut (supplied) straight in. If mounted at an angle it cannot be
tightened properly.
•
When tightening the M18 nut (supplied), firmly hold the main body down. The
case of the main body may be damaged if held in place with a tool such as pliers.
•
When tightening the M18 nut (supplied), if excess force is applied to the nut with a
tool such as pliers, it may bend it out of shape. Therefore, do not apply excess force.
■
Operation mode selector switch
With the operation mode selector switch, you can select either the LIGHT-ON mode (L) or the
DARK-ON (D) mode.
■
Reflective type (PZ-G41/G42/G101/G102/G10R/G10G/G10B
Series)
The following assumes LIGHT-ON (L) is set.
To use the sensor in DARK-ON mode, adjust the mode selector switch to "D".
■
Thrubeam type (PZ-G51/G52 Series) / Retro-reflective type (PZ-G61/G62
Series)
The following assumes DARK-ON (D) is set.
To use the sensor in LIGHT-ON mode, adjust the mode selector switch to "L".
* The pin numbers represent those of the connector type / pigtail quick disconnect type.
The model name with "C" (PZ-GxxCx) is the connector type, and the model name with "E"
(PZ-GxxEx) is the pigtail quick disconnect type.
Precautions on Regulations and Standards
Part Names
Mounting Method
Self-contained
Photoelectric Sensor
Sensitivity
adjustment
trimmer
« Transmitter side »
« Receiver side »
Power indicator light
(orange)
Output indicator light
(orange)
Stable operation indicator
(green)
Operation mode
selector switch
Light indicator
(red)
Sensitivity adjustment
trimmer
Light indicator
(red)
« Transmitter side »
« Receiver side »
Power indicator light
(orange)
Output indicator light
(orange)
Stable operation
indicator
(green)
Operation mode
selector switch
Operation mode
selector switch
Sensitivity adjustment
trimmer
Stable operation
indicator
(green)
Output indicator
light (orange)
Operation mode
selector switch
Sensitivity adjustment
trimmer
Output indicator light
(orange)
Stable operation
indicator
(green)
M3
25.4mm
24.1mm
Sensitivity Adjustment Method
Caution
Avoid using excess force when rotating the
sensitivity adjustment trimmer and
operation mode selector switch as it may
cause damage.
Sequence
Adjustment method
Sensitivity adjustment
trimmer
Position target in place. Slowly rotate the sensitivity trimmer
from the MIN position towards the MAX position until the
(orange) output indicator turns on (Position "A"). If the output
indicator does not turn off, even at MIN, then MIN is considered
Position "A".
Remove the target. Adjust the sensitivity trimmer from MIN
towards MAX until the (orange) output indicator turns on
(Position "B"). If the output indicator does not light up, the MAX
position is considered Position "B".
Adjust the sensitivity trimmer to the midpoint between "A" and
"B". Verify that the (green) stable operation light turns on with
and without a target in place.
Sequence
Adjustment method
Sensitivity adjustment
trimmer
Remove the target. Adjust the sensitivity trimmer to MAX. Mount
the sensor heads in place so the (orange) output indicator turns
off (on thrubeam models, the red light on the receiver face will
turn on)
Position target in place. Verify that the orange output indicator
turns on (on thrubeam models, the red light on the receiver face
will turn off). Adjust sensitivity lower if the output indicator does
not turn on (or if the red light on the receiver face does not turn
off on thrubeam models)
I/O Circuit Diagram
● PZ-G5xN/G5xP/G5xB
(Transmitter side)
● PZ-G5xN (Receiver side)/
G4xN/G10xN/G6xN
● PZ-G5xP (Receiver side)/
G4xP/G10xP/G6xP
● PZ-G5xB (Receiver side)/
G4xB/G10xB/G6xB
Panel (5 mm or less)
φ18.5 ± 0.2 mm
Panel cut size
Note
L
D
L
D
LIGHT-ON setting
DARK-ON setting
MIN
MAX
A
MIN
MAX
B
MIN
MAX
A
B
Reference
MIN
MAX
Reference
DC10-30V
0V
Brown(pin )
Blue(pin )
Photoelectr
ic sensor main circ
u
it
1
3
DC10-30V
NPN control output
0V
Brown(pin )
Black(pin )
Blue(pin )
Photoelectr
ic sensor main circ
u
it
O
verc
u
rrent
protection
circ
u
it
M8 connector
1
2
3
4
1
4
3
M12 connector
1
4
2
3
Load
DC10-30V
PNP control output
0V
Brown(pin )
Black(pin )
Blue(pin )
Photoelectr
ic sensor main circ
u
it
O
verc
u
rrent
protection
circ
u
it
1
4
3
Load
DC10-30V
0V
Brown(pin )
Blue(pin )
PNP control output
O
v
erc
u
rrent
protection circ
u
it
NPN control output
White(pin )
Photoelectr
ic sensor main circ
u
it
1
2
3
Load
Load
4
Black(pin )
Black(pin )
Black(pin )
PZ-GxxCN/GxxCP........................................................ M8 connector
PZ-GxxCB/GxxEN/GxxEP ............................................ M12 connector
96M11227