Judgment processing flow

This section describes the basic judgment processing flow of this device.

Trigger input

BUSY output

Total status

output

Trigger input

Inputs the imaging startup signal by synchronizing to the

target position from a photoelectric switch or PLC.

Also, the trigger can be input at a regular interval with an

internal trigger function.

Imaging

Light up the built-in light and image the target by using the

CMOS image sensor. BUSY output function turns ON.

Status output

Outputs the status results.

When the total status result is OK, the total status output

is ON.

When the total status result is NG, the total status NG

output is ON.

Save images

Saves the image to the image history memory in the sensor.

Conditions for saving the image can be selected from “NG

only” or “All”.

Color type can save 100 images, and monochrome type

can save 300 images.

Tool processing

According to the settings of a detection tool, the image of the target

is scanned for detecting whether a target is high or low quality.

Up to 16 detection tools can be set. Also, misaligned

positions of the target can be corrected by using the

position adjustment tool.

After the detection process is completed, the BUSY output

function turns OFF.