beautypg.com

KEYENCE IV Series User Manual

Page 77

background image

4-9

- IV Series User's Manual (Monitor) -

z

z

Internal trigger

(1)

(2)

(3)

Internal trigger

Imaging/

internal processing

Status output

Trigger interval Trigger interval

(1) The trigger will be input automatically according to the trigger interval settings.
(2) Performs the internal processing after the imaging.
(3) Outputs the status result.

z

z

External trigger

(1)

(2)

(3)

External trigger

Imaging/

internal processing

Status output

Trigger delay

(1) Start imaging by inputting the trigger at an arbitrary timing.

When the trigger delay interval is set, the imaging start time will be delayed in the specified period.

(2) Performs the internal processing after imaging.
(3) Outputs the status result.

Trigger Options

Auto Brightness Adjustment Focus Adjustment Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)