Stabilizing the Judgment Process
Correcting the distorted images due to
the installation
If the sensor is not installed just in front of the target
due to the sensor installation restrictions and/or to
prevent a shine on the target’s surface, the target
image may become trapezoidally distorted.
The tilt correction corrects these images and
displays them without distortion.
Top view
Lateral view
Before tilt
correction
After tilt correction
(vertical)
Indicator light
Target
Target
Achieving adequate image brightness
If the image is too dark, the judgment process for
high and low-quality-targets becomes unstable due
to poor contrast. Also, if the image is too bright,
the judgment process may become unstable.
Brightness can be adjusted in Auto Brightness
Adjustment.
“Auto Brightness Adjustment” (Page 4-11)
z
If the brightness cannot be adjusted
in the Auto Brightness Adjustment
Finer brightness adjustments can be made in
Advanced Brightness Adjustment.
“Advanced Brightness Adjustment”
z
z
Bright
Setting a higher brightness value gives a longer
exposure time, resulting in a brighter screen.
z
z
Imaging Mode
When "HighGain" is selected in the imaging
mode, the brightness amplification factor
increases and the screen becomes brighter.
z
If the brightness cannot be adjusted
due to uneven brightness
Refer to “Reducing the shininess of the
glossy or metal surface” (Page 5-35).