Error Messages

Checking errors by observing the PWR/ERR indicator light of the sensor

The causes of, and remedies for, an error can be checked by observing the indicator light of the sensor.

PWR/ERR

indicator light

PWR/ERR

indicator

status

Cause

Remedy

Green

ON

In operation.

-

Blink Setting in progress.

Operation stopped.

-

Red

ON

A system error occurred.

y

Turn on the power of this device.

y

If the same error occurs, contact your nearest

KEYENCE office.

A startup memory read error

occurred.

y

A data abnormality occurred

due to noise or because the

power switched OFF while

writing was in progress.

y

Initialize the settings.

y

If the same error occurs, contact your nearest

KEYENCE office.

Blink

A trigger error occurred.

A judgment process is not

performed.

y

If a target is to be imaged

using an external trigger, the

external trigger will be input

during a BUSY status.

y

If a target is to be imaged

using an internal trigger, the

trigger interval will become

shorter than the processing

time.

y

The trigger error can be fixed using one of the

following procedure.

y

Next normal trigger input

y

Clear Error input

y

Switching the program number

y

Proceeding to the settings screen of the sensor

y

Do not input an external trigger during a BUSY status.

y

Set the trigger interval of the internal trigger to a value

that is longer than the processing time.

y

An error will not occur if the trigger is set to [OFF]

described in output assignment for the Settings

Navigator (Page 4-60).

An external master image

registration error (without

registered master image)

occurred. The master image

is not updated.

y

The image to be registered

as a master image was not

imaged.

y

The work memory is

insufficient.

y

An external master image registration error can be

fixed using one of the following procedures.

y

Successful next external master image registration

y

Clearing the Error input

y

Switching the program number

y

Proceeding to the settings screen for sensor

y

Taking an image to be registered as a master image

and register it as an external master image.

y

Deleting one or more detection tools.

Error Messages