KEYENCE IV Series User Manual
Page 223
6-47
- IV Series User's Manual (Monitor) -
Setting the Advanced Monitor Information
4
Tap the [OK] button.
The monitor restarts.
After the restart, the sensor connection setup
screen opens.
z
z
Searching for and connecting to sensors on
the network
Tap the [Search Sensor] button.
The searched result will be displayed.
Select the sensor to be connected using the [<]
or the [>] button and tap the [Connect] button.
After connecting, the run screen or the Sensor
Setup Menu screen opens.
When a sensor without a set IP address is
selected and the [Connect] button is tapped,
the confirmation dialog appears.
The information dialog appears when the [OK]
button is tapped. The screen to set the sensor
network settings opens when the [OK] button
is tapped.
Tap the [Edit] button, set the IP address, the
subnet mask, and the default gateway, and
then tap the [Connect] button.
y
BOOTP is used for assigning the IP address
to the sensor.
“Settings after initialization” (Page A-40)
y
The search time is about 10 seconds.
y
Searching range and retrievable number of
units are as follows.
y
Sensor with no IP address (default) :
A maximum of 8 units can be retrieved
within a range that the BOOTP packet from
the sensor reaches (Page A-40).
y
Sensor with IP address :
A maximum of 16 units can be retrieved on
the local network to which the monitor is
connected.
6
Useful Features/V
arious Functions