KEYENCE IV Series User Manual
Page 182
6-6
- IV Series User's Manual (Monitor) -
List of the Useful Features
Items
Things you want to do
Useful functions
Description
Reference
page
I/O lines
Confirm whether or not the
input and output lines are
correctly wired
I/O Monitor
The operation test for the input
and output line can be performed.
Switch to NPN output or PNP
output
Polarity
The polarity can be changed
to NPN or PNP according to
the controlling device used.
Switch the output to N.O. or N.C. Output Settings
The settings for each OUT can
be changed to N.O. or N.C.
Output the status output with
one-shot
Common Output
Settings
The output can be changed
from latching output to one-
shot output.
Output the status output with
on-delay
Common Output
Settings
On-delay time can be set for
the one-shot output.
Switch the external trigger to
rise or fall
Input Settings
Rising trigger or falling
trigger can be selected as
the operation of the external
trigger
Output the NG status results Total status NG
output
When the total status result
of each detection tool was
NG, the total status NG output
function turns ON.
Confirm whether or not the
sensor is running properly
RUN output
When the sensor is running
with no system error occurring,
the output function turns ON.
Form a logical operation of
status result
Logic output
Logical operation result of each
detection tool can be assigned
to the output function.
Change the total status
conditions
Total status
conditions
The total status conditions can
be selected from [All Tools OK]/
[Any Tool OK]/[Logic 1] to [Logic
4].
6
Useful Features/V
arious Functions