Setting the trigger options, Setting the trigger options -10 – KEYENCE IV Series User Manual
Page 78
4-10
- IV Series User's Manual (Monitor) -
Setting the Trigger Options
1
Start the Settings Navigator.
“Starting the Settings Navigator” (Page 4-3)
2
Display the main screen for the Image
Optimization.
“Settings Navigator screen and operation flow”
3
Tap the [Trigger Options] button.
The screen to set the Trigger Options opens.
4
Select the trigger type.
Select the [Internal] or [External] button.
5
Set the trigger interval or trigger delay.
z
z
When the [Internal] is selected in step 4
Set the trigger interval within the range of 1 to
10000 ms.
If the internal trigger time is shorter than the
processing time (Page 5-40), a trigger error
occurs.
z
z
When the [External] is selected in step 4
Set the trigger delay within the range of 1 to
1000 ms.
The setting of the trigger interval and trigger
delay can be changed by using the slider or
inputting the value.
“Editing the value with the slider” (Page 3-14)
6
After the setting is completed, tap the [OK]
button.
The system returns to the main screen for the
Image Optimization.
Trigger Options
Auto Brightness Adjustment Focus Adjustment Extended functions
1. Image Optimization
2. Master Registration
3. Tool Settings
4. Output Assignment
4
Settings Navigator (Setting the Judgment Condition)