A-25

- IV Series User's Manual (Monitor) -

A

Error Messages

Message

Cause

Remedy

Output/

Indicator

Some tools can not correctly judge

because of insufficient outline

extraction amount as a result of

“Ext. Master Save”.

(Matching rate is 0.)

Check tool configuration.

An external master image

registration error (with

registered master image)

occurred. The following

errors occurred even

though the image was

updated and registered

as a master image.

y

For the new master

image, the outline

cannot be extracted

with the outline tool.

y

For the new master

image, the area cannot

be extracted with the

Color Area/Area tool.

y

The brightness

correction cannot be

performed correctly for

the new master image.

y

An external master image

registration error can be fixed

using one of the following

procedures.

y

Successful next external

master image registration

y

Clearing the Error input

y

Switching the program

number

y

Proceeding to the settings

screen of the sensor

y

Checking that the image to be

registered and the detection

tools/position adjustment

settings are applicable.

y

Adjusting the brightness of the

image to be registered properly.

*2

Some tools can not correctly

judged because area is 0 as a

result of “Ext. Master Save”.

(Matching rate is 0.)

Check tool configuration.

Brightness of brightness adjustment

area is not adjustable as a result of

“Ext. Master Save”.

Check configuration of brightness

adjustment.

Outer master registration fails

because image is not captured.

An external master image

registration error (with no

registered master image)

occurred. The master

image is not updated.

y

The image to be

registered as a master

image was not imaged.

y

The work memory is

insufficient.

y

An external master image

registration error can be fixed

using one of the following

procedures.

y

Successful in next external

master image registration

y

Clearing the Error input

y

Switching the program

number

y

Proceeding to the settings

screen of the sensor

y

Taking an image to be

registered as a mater image

and registering it as an external

master image.

y

Deleting one or more detection

tools.

*2

Outer master registration fails

because of lack of work memory.

Monitor fatal error (XXX) occurred.

Contact your nearest KEYENCE

office.

A system error occurred

in the monitor.

y

It is conceivable that a

fault occurred inside the

monitor.

y

Turn on the monitor power again.

y

If the same error occurs,

contact your nearest KEYENCE

office.

*3

Monitor system error happens.

Turn on monitor.

If not turned on, contact local

service center.