6-9
- IV Series User's Manual (Monitor) -
Changeover for a Target (Program Functions)
Preparing the program functions
Registers the judgment condition for each product
to the program before running.
Preparation flow
(1) Select a program number
Select a program number to register a judgment
condition from PROG00 to PROG31.
(2) Set a judgment condition in the Settings
Navigator
Set the judgment condition for a product in the
Settings Navigator.
(3) Select a program switch method
Select a switch method. There are methods
such as switching from the external input line or
switching by tapping the monitor.
The following functions can be used with the
preparations for the program function.
y
The product name can be registered to the
program.
“Editing a program name” (Page 6-12)
y
To register a similar product, the program can
be copied, and then the settings can be edited.
“Copying a program” (Page 6-12)
y
Initializes and returns the judgment condition
registered in the program to the status before
setting.
“Initializing a program” (Page 6-13)
Preparation procedures
1
Display the Sensor Setup Menu screen.
“Displaying the Sensor Setup Menu Screen”
2
Select a program number to register a
judgment condition of a product.
Select the
program
The program can also be selected from the
3
Set a judgment condition in the Settings
Navigator.
“Chapter 4 Settings Navigator (Setting the
Judgment Condition)” (Page 4-1)
4
Repeat steps 2 and 3 to register programs
for the number of products that are to be
changed over.
6
Useful Features/V
arious Functions