beautypg.com

KEYENCE IV Series User Manual

Page 283

background image

A-27

- IV Series User's Manual (Monitor) -

A

Error Messages

Message

Cause

Remedy

Output/

Indicator

This file configuration data is for

xxxx.

This file is not readable.

The setting files for a

different model of sensors

cannot be read.

Read the setting files of a sensor

of the same model.

FTP Connection Error

Connection with the FTP

server failed.

Refer to “Remedy when data

transfer via FTP is unavailable”

(Page A-38).

*2

FTP Transfer Error

(Transfer Failed)

Data transfer to the

transfer destination folder

failed.

FTP Transfer Error

(Insufficient Data Buffer)

Data which is larger than

the remaining storage of

the FTP buffer has been

created and the transfer

failed.

*1 Error output from the sensor: ON, PWR/ERR indicator light of the sensor: Lighting (red),

PWR indicator light of the monitor: Lighting (red)

*2 Error output from the sensor: ON, PWR/ERR indicator light of the sensor: Blinking (red),

PWR indicator light of the monitor: Blinking (red)

*3 PWR indicator light of the monitor: Lighting (red)
*4 SENSOR indicator light of the monitor: Off