Status table – KEYENCE IV Series User Manual

Page 259

background image

A-3

- IV Series User's Manual (Monitor) -

A

Status Table

Status table

Status

Monitor

screen

type

Sensor operation indicator light

Input

Output

PWR/ERR

OUT

TRIG

External

trigger

Switch

programs

External

master image

registration

Clear

Error

BUSY

Total Status / Total status NG /

Each tool / Each logic /

Pos.Adj.

*1

RUN

Error

Running

*2

Waiting for a trigger

RUN

Lighting

(green)

*3

OFF

¡

¡

¡

Í

OFF

*4

ON

OFF

Judgment processing

*5

*6

*7

*8

ON

Switching programs

*9

OFF

*10

*11

*12

Registering the external master image

*11

*10

Setting

Limit Adjustment

TEST

Blink

(green)

OFF

*5

¡

Н

Н

Н

Same

as while

running

OFF

OFF

OFF

Trigger Options, Master Registration, etc.

LIVE

Focus adjustment (MF)

OFF

*14

OFF

Automatically adjusting the brightness

Automatically adjusting the focus (AF)

Blink

(green)

OFF

*13

Í

*13

Setup Adjustment

-

*15

OFF

I/O Monitor

OFF

*16

Others

Н

Н

Н

Н

OFF

OFF

OFF

Error

Trigger error

Running

RUN

Blink (red)

Same as normal

Same as normal

¡

Same as normal

ON

Setting

LIVE

External master registration error

-

System error

Lighting

(red)

OFF

OFF

Н

Н

Н

Н

OFF

OFF

OFF

Startup memory readout error

*17

*17

*17

*6 Disregards the input. A trigger error occurs.

*7 Stops the judgment process and switches over.

*8 Stops the judgment process and registers the previously taken image as a master image.

*9 Turns off the light before the process is completed. Until the light turns off, the previous status result

will be displayed.

*10 After the current process is completed, generates the new input.

*11 Do not use. The processing order becomes indeterminate.

*12 Turns OFF before the process is completed. Outputs the previous status result until this turns OFF.

*13 The internal trigger is issued automatically and the image will be updated. The Busy output operates.

*14 The flashing cycle of the orange light changes by linking to the focus indicator. The STATUS indicator

light operates in the same way.

*15 The internal trigger is issued automatically and the image is updated.

*16 While the I/O monitor function is used, only the operation of the I/O lines is confirmed. The assigned

functions will not operate.

*17 The NPN open collector output turns OFF regardless of the output settings (N.O./N.C.) and the

polarity (NPN/PNP) settings.

Additionally, refer to “Chapter 7 Controlling with Input/Output Line” (Page 7-1).