KEYENCE FS-22X User Manual
Instruction manual, Dual digital fiber sensor, Safety precautions
1
Dual Digital Fiber Sensor
FS-V22/22G/22R(P)/20R/22X
Instruction Manual
Read this manual before using the product in order to achieve
maximum performance.
Keep this manual in a safe place after reading it so that it can be
used at any time.
1. Safety Precautions
WARNING
• This product is just intended to detect the object(s). Do not use this
product for the purpose to protect a human body or a part of human
body.
• This product is not intended for use as explosion-proof product. Do
not use this product in a hazardous location and/or potentially explo-
sive atmosphere.
• This product is a sensor of DC power supply type. Do not apply AC
power. The product may explode or burn if 100 VAC or a higher volt-
age is applied.
■ UL Certificate
This product is an UL/C-UL Listed product.
• UL File No. E301717
• Category NRKH, NRKH7
• Enclosure Type 1 (Based on UL50)
Be sure to consider the following specifications when using this product
as an UL/C-UL Listed Product.
• Use the power supply with Class 2 output defined in NFPA70 (NEC:
National Electrical Code).
• Use with the over current protection device which is rated 30V or more
(rated 40V or more for NPN output type) and not more than 2A.
Check that all the accessories are ready before use.
■ Accessories
Instruction manual (x1) End units (x2)
Expansion Sticker (x1)
2. Part Names
Operation indicator*
Digital
monitor
Preset value (PV)
green indicator
Current value
(CV) red indicator
Dust cover
Fiber lock lever
Set button
Manual
button
Mode button
Expansion protective cover
Expansion connector
Output selector
Cable
3. Amplifier Expansion
Up to 16 expansion units can be connected
to each main unit.
1) Remove the expansion protective cover
from the main unit.
2) Mount each amplifier to the DIN rail.
3) Press the two claws of each expansion
unit to the grooves on the main unit
until the claws snap.
4) Mount the end units to the left- and
right-hand sides of the whole amplifi-
ers in the method shown in the figure
at step 2.
5) Check that the amplifiers are securely sand-
wiched by the end units. Use a Phillips screw-
driver and securely tighten the screws on the
end units (i.e., two screws on each end unit).
4. Connecting Fiber Unit
Fiber insertion sign
1) Open the dust cover in the direction
shown by arrow
➀.
2) Move down the fiber lock lever in the
direction shown by arrow
➁.
3) Insert a fiber unit into the fiber inser-
tion holes to a length of the fiber in-
sertion sign (i.e., approximately 14
mm).
4) Move up and return the fiber lock lever
in the direction shown by arrow
➃.
Note:If a thin fiber unit is used, an adapter provided with the thin fiber unit
will be required.
Unless the right adapter is connected, the thin fiber unit will not
detect targets correctly.
Cable outer dia.
Adapter
Appearance
ø1.3
Adapter A
ø1.0
Adapter B
• To connect the coaxial reflective type fiber unit to the amplifier, connect
the single-core fiber to the transmitter side, and connect the multiple-
core fiber to the receiver side.
Single-core fiber
Multi-core fiber
Transmitter
Receiver
• To remove the amplifiers added, take the steps opposite to the mount-
ing procedure.
• Put the provided sticker close to the sensor.
Note • The FS-V22/22G/22R(P)/20R/22X incorporates a mutual
interference prevention function, thus allowing the close mounting
of a number of fiber units in the following modes.
Power mode
Number of
units connected
FINE
4
TURBO
8
SUPER
TURBO
8
ULTRA
TURBO
8
5. I/O Cricuit
Refer to the following I/O circuit diagram when connecting the unit to pe-
ripheral devices.
● FS-V22/22G/22R/22X
● FS-V22RP
0 V
Max. 20mA
DC 5 to 40V
(Control output)
Load
Black
Photoelectric
sensor main circuit
Overcurrent
protection circuit
DC 12 to 24V
Max. 20mA
0V
(Control output)
Load
Black
Photoelectric
sensor main circuit
Overcurrent
protection circuit
* The operation indicator of the FS-V22X (infrared model) will not be lit.
96M11224
Document Outline
- 1. Safety Precautions
- 2. Part Names
- 3. Amplifier Expansion
- 4. Connecting Fiber Unit
- 5. I/O Cricuit
- 6. Making Sensitivity Settings
- 7. Selecting Output
- 8. User-friendly Functions
- 9. Key Lock
- 10. Mode Settings before Shipping (Initialization)
- 11. Hints On Correct Use
- 12. Specifications
- 13. List of Digital Display Items
- WARRANTY