Extended functions for the output assignment, Extended functions items for the output assignment, Extended functions for – KEYENCE IV Series User Manual
Page 130: The output assignment -62, Extended functions items for
4-62
- IV Series User's Manual (Monitor) -
Extended functions for the Output Assignment
Extended functions items for the Output Assignment
Items
Description
Setting range
Default
value
Logic Settings
Assigns the logical operation
results of each detection tool to
the output function.
Up to 4 items, Logic 1 to 4, can
be defined.
y
Unused
The selected items are not used in
a logical formula.
y
Used
When the status results of the
selected items were OK, the total
status output function turns ON.
y
Used (Inverse)
When the status results of the
selected items were NG, the total
status output function turns ON.
Unused
Logic
Selects the logical operation
method of logics.
y
AND
Calculates the logical multiply
(AND) of all selected items.
y
OR
Calculates the logical sum (OR) of
all selected items.
AND
Total Status
Conditions
Selects a condition for the total
status result. The total status
result is displayed in accordance
with the selected condition.
y
All Tools OK
When all of the status results of the
detection tools was OK, the total
status output function turns ON.
y
Any Tools OK
When any of the status results of
the detection tools was OK, the total
status output function turns ON.
y
Logic 1 to 4
When the status result of the set
logic was OK, the total status
output function turns ON.
All Tools OK
Output Assignment
Extended functions
1. Image Optimization
2. Master Registration
3. Tool Settings
4. Output Assignment
4
Settings Navigator (Setting the Judgment Condition)