beautypg.com

Confirming the status by observing – KEYENCE IV Series User Manual

Page 290

background image

A-34

- IV Series User's Manual (Monitor) -

A

Remedy when the Monitor cannot be Connected with the Sensor

Confirming the status by observing the SENSOR indicator light of the monitor

The causes of an unavailable connection and countermeasures can be confirmed by checking the

SENSOR indicator light of the monitor.

SENSOR indicator light

Status of

the SENSOR

indicator light

Status

Remedy

Green

ON

Correct connection with the

sensor.

-

Blink

No correct connection with the

sensor.

The link with the sensor or

the Ethernet switch has been

established, but connection

with the sensor has not been

established.

For direct connection

“Remedy when direct connection is unavailable”

(Page A-28)
For network connection

“Remedy when connection via a network is unavailable”

(Page A-29)

OFF

No correct connection with the

sensor.

The link with the sensor or the

Ethernet switch has not been

established.

y

Supply power to the monitor.

y

Supply power to the sensor or the Ethernet switch of

the connection target.

y

Connect the cable correctly.

y

The communication timeout interval is 1 minute.

y

During the timeout interval after trouble has occurred, the screen may fail to be updated while the

SENSOR indicator light in on, or the monitor may not accept an operation.