beautypg.com

Using the program functions (changing over), Using the program functions, Changing over) -10 – KEYENCE IV Series User Manual

Page 186: When the [monitor/pc] is selected in, The program switch method -10

background image

6-10

- IV Series User's Manual (Monitor) -

Changeover for a Target (Program Functions)

5

Select a program switch method.

“Program Switch Method” (Page 6-42)

y

Monitor/PC ....... Switching by tapping the

monitor screen or operating

from the IV-Navigator (IV-H1)

or the field network.

y

External IN ....... Switching by inputting signals

from PLC to the input line of

the sensor.

6

If the [External IN] is selected in the

program switch method, set the input

terminal.

“Input Settings” (Page 6-26)

The bit to be set differs depending on the
product numbers to be registered.

Product numbers to

be registered

(Program numbers)

bit to be assigned

to the input line

2

bit0

3 to 4

bit0/bit1

5 to 8

bit0/bit1/bit2

9 to 16

bit0/bit1/bit2/bit3

17 to 32

bit0/bit1/bit2/bit3/bit4

Setup example

When 7 types of products are to be registered,

bit0, bit1, and bit2 are assigned to arbitrary IN

terminals. bit3 and bit4 are not assigned.

Using the program functions

(changing over)

When the [Monitor/PC] is selected in the

Program Switch Method

1

Display the Sensor Setup Menu screen.

“Displaying the Sensor Setup Menu Screen”

(Page 6-7)

2

Select the program number that the

product to be judged is registered.

Select the

program

The program number can also be selected

while confirming a master image with the

[Detail] button (Page 6-7).

3

Tap the [RUN] button and the run mode

will start with the new program.

For details of how to switch from the IV-Navigator

(IV-H1), refer to "IV Series User's Manual (PC

Software)".

6

Useful Features/V