Using the program functions (changing over), Using the program functions, Changing over) -10 – KEYENCE IV Series User Manual
Page 186: When the [monitor/pc] is selected in, The program switch method -10
6-10
- IV Series User's Manual (Monitor) -
Changeover for a Target (Program Functions)
5
Select a program switch method.
“Program Switch Method” (Page 6-42)
y
Monitor/PC ....... Switching by tapping the
monitor screen or operating
from the IV-Navigator (IV-H1)
or the field network.
y
External IN ....... Switching by inputting signals
from PLC to the input line of
the sensor.
6
If the [External IN] is selected in the
program switch method, set the input
terminal.
The bit to be set differs depending on the
product numbers to be registered.
Product numbers to
be registered
(Program numbers)
bit to be assigned
to the input line
2
bit0
3 to 4
bit0/bit1
5 to 8
bit0/bit1/bit2
9 to 16
bit0/bit1/bit2/bit3
17 to 32
bit0/bit1/bit2/bit3/bit4
Setup example
When 7 types of products are to be registered,
bit0, bit1, and bit2 are assigned to arbitrary IN
terminals. bit3 and bit4 are not assigned.
Using the program functions
(changing over)
When the [Monitor/PC] is selected in the
Program Switch Method
1
Display the Sensor Setup Menu screen.
“Displaying the Sensor Setup Menu Screen”
2
Select the program number that the
product to be judged is registered.
Select the
program
The program number can also be selected
while confirming a master image with the
3
Tap the [RUN] button and the run mode
will start with the new program.
For details of how to switch from the IV-Navigator
(IV-H1), refer to "IV Series User's Manual (PC
Software)".
6
Useful Features/V
arious Functions