Remedy when the Monitor cannot be Connected with the Sensor

Status

Remedy

Connection is not possible using the [Specify

Sensor] button or the [Connect] button on

the Sensor Connect screen.

When the connection cannot be established by

specifying the sensor

y

Supply power to the sensor and the network equipment.

y

Correctly connect with the sensor and the network equipment.

“Connecting via network” (Page 2-16)

y

Specify the correct IP address of the sensor.

y

If the sensor IP address has not been set, establish a

connection using the [Search Sensor] button.

“Searching for and connecting to sensors on the network”

(Page 6-47)

y

Confirm that the IP address of the monitor does not

coincide with that of the sensor or another device. Also,

correctly set the subnet mask and the default gateway.

“Confirming/Setting the IP address of the monitor”

(Page A-36)

y

Change to direct connection and confirm that the IP

address of the sensor does not coincide with that of the

monitor or another device. Also, correctly set the subnet

mask and the default gateway.

Also, reset (initialize) the network setting for the sensor.

“When directly connecting with the sensor” (Page 6-46)

“Confirming/Setting the IP address of the sensor”

(Page A-37)

“Initializing the Network Settings (IP Reset Switch)”

(Page A-40)

First connection after purchasing, or

connection after monitor initialization.

y

Tap the [Search Sensor] button to search for the sensor.

“Searching for and connecting to sensors on the

network” (Page 6-47)

If a connection is unavailable, refer to “When the

connection cannot be established by searching for the

sensor” (Page A-30).

y

Tap the [Specify Sensor] button to connect.

“Specifying the IP address of and connecting to the sensor”

(Page 6-48)

If a connection is unavailable, refer to “When the

connection cannot be established by specifying the sensor”

(Page A-31).