Clearing errors, Clearing errors -10, Clearing errors 7 – KEYENCE IV Series User Manual
Page 240
7-10
- IV Series User's Manual (Monitor) -
Clearing Errors
If an error targeted for clearing has occurred, outputting an error can be turned OFF by the clear error input.
Error output
Clear Error input
Min 2 ms
(Min 2 ms)
T5
(1)
(2)
ON
OFF
ON
OFF
Error occurred
(1) If an error occurred, the error output turns ON.
Error types which can be output are as follows.
y
System error
y
Startup memory readout error
y
External master registration error
y
Trigger error
To output the trigger error, set the trigger error in the Output Assignment (Page 4-60) under Settings
Navigator to [ON].
y
FTP error
To output the FTP error, set the FTP error within the FTP settings (Page 6-32) to [Enable].
(2) The error output can be turned OFF by the clear error input. Minimum ON/OFF input time is 2 ms.
Errors which can be cleared are as follows.
y
External master registration error
y
Trigger error
y
FTP error
The system error/startup memory readout error cannot be cleared.
y
For details on T5, refer to “Input Response Time” (Page 7-12).
Clearing Errors
7
Controlling with the Input/Output Line