Tool Auto Tuning (Automatically Adjusting the Judgment Condition)

5

Check the changes in settings after the

auto tuning is performed, and tap the [OK]

button.

Changed

settings

If the auto tuning has failed, follow the message
to change the tool settings or the image to be
registered.

The type of an image to be registered will be

displayed on the upper right on the screen.

y

: Registers as an OK image.

y

: Registers as an NG image.

The confirmation dialog to continuously register
another image appears.

6

Tap the [Yes] button and repeat steps 3 to 5.

y

Registering one or more OK images and NG
images is recommended.

y

Up to 24 images can be registered.

7

After the registration is completed, tap the

[No] button on the confirmation dialog.

The system returns to the main screen for Tool
Auto Tuning.

“Starting and finishing the Tool Auto Tuning”

(Page 5-16)

Registering the images from the image

history saved in the sensor

Registers the image as an OK or an NG image to
perform tuning while checking the images loaded
from the Sensor Image History.

1

Display the main screen for Tool Auto

Tuning.

“Starting and finishing the Tool Auto Tuning”

(Page 5-16)

2

Tap the [Sensor Image History] button.

The Sensor Image history screen opens.

3

Tap the image history to be the OK or NG

image and tap the [Zoom] button.

Select the

image

The selected image will be enlarged.

4

Check the displayed image and tap the

[AutoTune as OK] or [AutoTune as NG]

button.

y

By tapping [<]/[>] button, you can check the

other images in enlarged display.

y

The status result displayed on the screen is

the status result by the settings at the time

of saving the image. If the tool settings are

changed after the image is saved, only the

frame of the tool window will be displayed

regardless of selection of the tool display

method (Page 5-7). The processing status

will not be displayed.

5

Operating/Adjusting