beautypg.com

KEYENCE IV Series User Manual

Page 245

background image

8-3

- IV Series User's Manual (Monitor) -

Specifications

Model

IV-500C IV-500CA IV-500M IV-500MA IV-150M IV-150MA IV-2000M IV-2000MA

Output

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable

For open collector NPN output : Maximum rating 26.4V 50mA,

remaining voltage 1.5V or lower

For open collector PNP output : Maximum rating 26.4V 50mA,

remaining voltage 2V or lower

Outputs

4 outputs (OUT1 to OUT4)

Function

Enable by assigning the optional functions

Assignable functions :

Total judge result, RUN, BUSY, Error, Position adjustment result,

Judge result of each tool, Logical operation result of each tool

Ethernet

*10

Standard 100BASE-TX/10BASE-T

Connector M12 4pin connector

Network function

FTP client, EtherNet/IP, PROFINET

Rating

Power

voltage

DC 24V ± 10% (including ripple)

Consumption

current

0.6A or less

Environmental

resistance

Ambient

temperature 0 to +50°C (No freezing)

Relative

humidity

35 to 85%RH (No condensation)

Vibration 10 to 55 Hz, 1.5 mm double amplitude, 2 hours each for X, Y, and Z axes

Shock

resistance 500m/s

2

6 different directions in 3 times

Enclosure

rating

*11

IP67

Material

Main unit case : Aluminum die-casting, Packing : NBR, Front Cover : Acrylic,

Mounting adapter : POM

Weight

Approx. 270 g

*1 The focusing position can be automatically adjusted at the time of installation. Disabled during the

operation.

The focusing position can be registered by programs.

*2 Tools can be installed by programs.

*3 Saves to the memory in the sensor.

The images saved in the sensor can be backed up to the USB memory installed to the intelligent

monitor (IV-M30) or to the PC by the software for IV (IV-H1).

*4 70 images when using the FTP client function

*5 210 images when using the FTP client function

*6 This can be displayed on the intelligent monitor (IV-M30) or by the IV software (IV-H1).

*7 Color type only.

*8 Monochrome type only.

*9 This function can be used with the software for IV (IV-H1).

*10 This is for connection with the intelligent monitor (IV-M30) or the IV software (IV-H1).

*11 Except when the polarizing filter attachment (OP-87436/OP-87437) is mounted.

8