KEYENCE OP-85135 User Manual
KEYENCE Sensors

Attachment / Slit Plate / Polarizing Filter for the PZ-G Series
Instruction Manual
● List of attachments / polarizing filters
A slit plate and polarizing filter can be installed in the thrubeam type sensors (PZ-G51/G52 Series).
Mount the slit plate and polarizing filter on the main body after assembling the attachment using the
following procedures. (The slit plate and polarizing filter can be mounted simultaneously.)
Before use, be sure to remove the protective seal from both sides of the polarizing filter.
● OP-85136 (attachment for square type sensors)
* The slit plate and polarizing filter are optional.
Assembling the attachment
Mounting onto the main body
● OP-85135 (attachment for threaded type sensors)
* The slit plate and polarizing filter are optional.
Assembling the attachment
Mounting onto the main body
•
Mount the slit plate and polarizing filter at the following position.
•
Receiver .................................................. Upper portion
•
PZ-G51 Series transmitter ...................... Upper portion
•
PZ-G52 Series transmitter ...................... Upper/lower portions
•
When mounting the slit plate and polarizing filter on the thrubeam type sensors (PZ-G51/52
Series) make sure the transmitter and receiver are mounted facing the same direction.
In addition, if a sensor is mounted adjacent to the existing one, mount the sensors so that
they face the opposite direction.
Example: When interference prevention is carried out for 4 sets
● OP-85137 (slit plate set)
Three types of slit plates with varying widths are available. Select according to your detection purposes
from the following list.
Name
Contents
Model No.
Attachment A
Square type attachment
× 2 pcs.
OP-85136
Attachment B
Threaded type attachment
× 2 pcs.
OP-85135
Slit plate set
0.5 mm, 1 mm, 2 mm
× 3 pcs. each
OP-85137
Polarizing filter A (red)
Red polarizing filter
× 2 pcs.
OP-85138
Polarizing filter B (infrared)
Infrared polarizing filter
× 3 pcs.
OP-85139
Important
Attachment
Slit plate
Polarizing filter
Cover
Attachment with the slit plate
and polarizing mounted
Photoelectric sensor head
The slit plate can be
mounted vertically.
When removing the cover,
use a screwdriver to hold
the hook down.
Attachment
Slit plate
Polarizing filter
Cover
Attachment with the slit plate and
polarizing filter mounted
Photoelectric sensor head
The slit plate can be
mounted vertically.
* When removing the cover,
use a screwdriver to hold
the hook down.
Contents
Slit plate
Slit plate + polarizing filter
Slit plate size (mm)
0.5
Ч5.0
1.0
Ч5.0
2.0
Ч5.0
No slit
plate
0.5
Ч5.0
1.0
Ч5.0
2.0
Ч5.0
Color of slit plate
Black
Blue
Gray
—
Black
Blue
Gray
Detecting
distance
(m)
PZ-G51
Series
1
2.5
5
9
0.5
1.5
3
PZ-G52
Series
2.5
5.5
10
15
1
2
5
Note
Mount only
on the upper
portion
Mount on
both the
upper/lower
PZ-G51 transmitter
PZ-G52 transmitter
Mount only
on the upper
portion
PZ-G51/G52 receiver
Receiver
Transmitter
Receiver
Transmitter
Transmitter
Receiver
Transmitter
Receiver
96M00080