beautypg.com

Outline tool, Setting items for the outline tool, Outline tool -32 – KEYENCE IV Series User Manual

Page 100: Setting items for the outline tool -32

background image

4-32

- IV Series User's Manual (Monitor) -

Outline tool

Setting items for the Outline tool

Items

Description

Setting range

Default value

Edit Window

Window Shape

Selects the window shape to

specify an area of the target

to be detected.

y ¨

Rect

Specifies with the rectangular window.

An arbitrary size, position, and angle

can be specified with stylus.

y ¡

Circle

Specifies with the circular window.

An arbitrary size and position can be

specified with stylus.

¨

Rect

Search Region

Specifies an area to search the

outline of a target. By specifying

the smaller area as a search

region, the processing time will

be shortened.

y

Entire

Specifies the entire imaging area as a

search region.

y

Partial

Specifies a search region to an arbitrary

size in the imaging area.

Entire

(Without position

adjustment)

Partial

(With position

adjustment)

Fine T

une
Outline

Remove Outline

Judges by disabling an

unnecessary outline which

interrupts the stabilized

detection. Specify by tracing

the extracted outline with stylus.

y

Undo

The previous operation can be cancelled.

You can undo back to 5 operations before.

y

Clear

Initializes all the disabling processes.

y

Eraser Width

Selects the eraser width (light/medium/

heavy) of the pen when specifying an

unnecessary outline.

Not specified

Sensitivity

The extraction sensitivity of

an outline can be selected

according to the target.

y

High

Extracts an outline of the image with

low contrast. Used when an outline you

wish to detect cannot be extracted.

y

Norm

Extracts the standard outline.

y

Low

Reduces the extracted volume of an

outline. Reduces the extracted volume of

an outline that is not necessary to detect.

Norm

Limit

Adjustment

Adjusts a threshold (matching

rate*) used in the OK/NG

judgment. During threshold

adjustment, the system turns

to the Test mode so that the

thresholds can be adjusted to

the applicable value during an

operation.

0 to 100

70

* 100 indicates that outline is completely matched.

Matching rate decreases in accordance with number of unmatched parts.

Outline tool

Color Area/Area tool

Position Adjustment tool

Extended functions

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)