Operation when the Power is Turned on
Operation flow when the power is
turned on
Initial start-up of the
monitor
y
Direct Connection
y
Network Connection
Run
Turn on the power
(1)
(2)
(5)
(4)
Connecting...
(3)
Sensor settings menu
Initial start-up of
the sensor
(1) When the power of the monitor is turned on for
the first time, set the display language, date and
time, and the connection method with the sensor.
For the connection method with the sensor, there
are Direct Connection and Network Connection.
“Operation for initial startup of the monitor
(Direct Connection)” (Page 3-6)
“Operation for initial startup of the monitor
(Network Connection)” (Page 3-7)
(2) When the power of the sensor is turned on for
the first time, set the polarity.
“Operation for initial startup of the sensor”
(3)
The Sensor Setup Menu screen opens. Set the
activation condition in Settings Navigator. After the
setting is completed, operation begins.
“Chapter 4 Settings Navigator (Setting the
Judgment Condition)” (Page 4-1)
(4) After the second time of starting the monitor
and sensor, the operation begins when the
power is turned on.
“Chapter 5 Operating/Adjusting” (Page 5-1)
(5) When the connection is failed, the process
remains in the connecting screen.
“Remedy when the Monitor cannot be
Connected with the Sensor” (Page A-28)
The sensor can be independently operated.