Set the output items to be assigned to the output
line (OUT1 to OUT4).

“Connecting the power I/O cable of the sensor”

(Page 2-12)

“Chapter 7 Controlling with Input/Output Line”

(Page 7-1)

Main screen for the Output

Assignment

(2)

(3)

(1)

(4)

(5)

(1) [Back] button

Returns to the Tool settings screen.

“3. Tool Settings (Setting the Judgment

Method for Targets)” (Page 4-28)

(2) Output assignment button

Assigns the output item to each output line.

(3) [ON]/[OFF] button for the trigger error output

Select whether to enable/disable the output
when the trigger error occurred.

“Error Messages” (Page A-22)

(4) [Complete] button

Finishes the Settings Navigator.

“Finishing the Settings Navigator” (Page 4-5)

(5) Extended functions display button

Displays the extended functions menu for the
Output Assignment.

“Display Method of Extended Functions

Menus” (Page 4-66)

Setting range of the Output

Assignment

Setting

range

Description

OFF

Do not output.

Output function will be constantly OFF.

Total Status

When the total status result of the

tools which have been set was OK,

the output function turns ON.

The condition of the total status can

be selected from [All Tools OK] /

[Any Tool OK] / [Logic 1] to [Logic 4].

Tot.

StatusNG

When the total status result was

NG, the output function turns ON.

RUN

When the sensor is running with no

system error occurred, the output

function turns ON.

BUSY

The output function turns ON when

the system is in a state that cannot

input additional trigger; such as

during imaging, judging processing,

switching programs, and registering

external master images.

Error

The output function turns ON

when an error has occurred; such

as system error, memory readout

error for startup, external master

registration error, trigger error (when

the trigger settings are enabled).

Pos. Adj.

When position adjustment processing

is finished normally, the output function

turns ON.

Tool 01 to 16

When the status result of specified

tool is OK, the output function turns

ON. Status results can be output for

each tool.

Logic 1 to 4 When the status result of specified logic

is OK, the output function turns ON.

z

„

Default value

OUT1

:Total Status (N.O.)

OUT2

:BUSY (N.O.)

OUT3

:Error (N.C.)

OUT4

:OFF

Trigger Error

:OFF

y

N.O./N.C. can be changed.

“Output Settings” (Page 6-27)

y

The input cable assignment can be changed.

“Input Settings” (Page 6-26)

4. Output Assignment

(Setting Details of Outputting to Output Line)

1. Image Optimization

2. Master Registration

3. Tool Settings

4. Output Assignment

4

Settings Navigator (Setting the Judgment Condition)