KEYENCE IV Series User Manual
Page 45
2-13
- IV Series User's Manual (Monitor) -
Cables
Wiring
color
Name
Assigning
default value
Description
Brown
DC24V
-
+ side of power
Blue
0V
-
- side of power
GND of input-output cable
Black
OUT1
Total Status (N.O.) Output assignable function
y
Total Status
y
Tot. StatusNG
y
RUN
y
BUSY
y
Error
y
Pos. Adj.
y
Judge result of each tool (Tool 1 to Tool 16)
y
Logical operation result of each tool (Tool 1 to Tool 4)
y
OFF (not used)
White
OUT2
BUSY (N.O.)
Gray
OUT3
Error (N.O.)
Orange
OUT4
OFF
Pink
IN1
External trigger ↑
Set external trigger.
Rising timing (↑) or falling timing (↓) can be set.
Yellow
IN2
OFF
Input assignable function
y
Program bit0 to bit4
y
Clear Error
y
Ext. Master Save
y
OFF (not used)
Light Blue IN3
OFF
Purple
IN4
OFF
Green
IN5
OFF
Red
IN6
OFF
Drain
FG
-
Insulated frame
Cable specification
y
Brown/Blue/Black/White/Gray/Orange : AWG25
y
Pink/Yellow/Light Blue/Purple/Green/Red : AWG28
y
With braided shield cable (with drain cable)
y
The output cable assignment can be changed.
“4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60)
y
N.O./N.C. can be changed.
y
The input cable assignment can be changed.
y
Individually insulate the non-used input-output cables.
y
For input cables of this sensor, connect with non-contact output (transistor output/SSR output).
For contact output (relay output), incorrect input may be operated due to the contact bouncing.
2
Installation and Connection