beautypg.com

Polarity, I/o monitor, Polarity -28 – KEYENCE IV Series User Manual

Page 204: I/o monitor -28

background image

6-28

- IV Series User's Manual (Monitor) -

Setting the Extended Functions of the Sensor

Polarity

1

Select the [NPN] or [PNP] under Polarity.

y

NPN
Output circuit ....NPN open collector
Input circuit .......No-voltage input

y

PNP
Output circuit ....PNP open collector
Input circuit .......Voltage input

“Cables” (Page 2-12)

2

Tap the [OK] button.

The confirmation dialog appears.

3

Tap the [OK] button.

The system returns to the Sensor Advanced screen.

I/O Monitor

Whether or not the I/O line for control is correctly
wired can be confirmed.

1

Tap the [Go] button in the I/O Monitor.

2

Set the I/O Monitor settings.

z

z

Input

Displays the input status of external input in
real time. Whether or not the ON/OFF output
from the PLC is being correctly input can be
confirmed.

z

z

Output

Tap the [ON] button to turn ON the each OUT
output. Tap the [OFF] button to turn them OFF.
Confirm that the PLC or the display lamp is
correctly output.

3

After the setting is completed, tap the

[Close] button.

The system returns to the I/O Settings screen of
the sensor.

6

Useful Features/V