Polarity, I/o monitor, Polarity -28 – KEYENCE IV Series User Manual
Page 204: I/o monitor -28
6-28
- IV Series User's Manual (Monitor) -
Setting the Extended Functions of the Sensor
Polarity
1
Select the [NPN] or [PNP] under Polarity.
y
NPN
Output circuit ....NPN open collector
Input circuit .......No-voltage input
y
PNP
Output circuit ....PNP open collector
Input circuit .......Voltage input
2
Tap the [OK] button.
The confirmation dialog appears.
3
Tap the [OK] button.
The system returns to the Sensor Advanced screen.
I/O Monitor
Whether or not the I/O line for control is correctly
wired can be confirmed.
1
Tap the [Go] button in the I/O Monitor.
2
Set the I/O Monitor settings.
z
z
Input
Displays the input status of external input in
real time. Whether or not the ON/OFF output
from the PLC is being correctly input can be
confirmed.
z
z
Output
Tap the [ON] button to turn ON the each OUT
output. Tap the [OFF] button to turn them OFF.
Confirm that the PLC or the display lamp is
correctly output.
3
After the setting is completed, tap the
[Close] button.
The system returns to the I/O Settings screen of
the sensor.
6
Useful Features/V
arious Functions