beautypg.com

Importing the status output, Importing the status output -4, Importing the total status – KEYENCE IV Series User Manual

Page 234: Total status ng output -4, Importing the status output 7

background image

7-4

- IV Series User's Manual (Monitor) -

Importing the Status Output

Imports the status output assigned to output line of power I/O cable. For details on assigning to output line,
refer to “4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60).

Importing the total status / total status NG output

Total status results of multiple detection tools and position adjustments for the examined target can be
checked.

Black line: OUT 1

Assign the total status/

total status NG output

White line: OUT 2

Assign the BUSY output

External trigger/Internal

trigger

Total status result of Trigger 1

Previous total status result

Processing time

Min 0.2 ms

ON

OFF

ON

OFF

Trigger 1

y

The operation example when the output mode (Page 6-27) of status output is set to [Latching]. When the
output mode is set to [One-Shot], refer to “Changing the timing of the status output” (Page 7-6).

y

The total status output turns ON when the total status results were OK.
The total status NG output turns ON when the total status results were NG.

The total status conditions can be selected from [All Tools OK], [Any Tool OK] and [Logic 1] to [Logic 4].

y

[All Tools OK]

When all of the status results of the detection tools and the adjustment result of the position

adjustment result were OK, the total status result is OK.

y

[Any Tool OK]

When any of the status results of the detection tools except that of the position adjustment was OK,

the total status result is OK.

y

[Logic 1] to [Logic 4]

When the logical operation result of the set detection tools was OK, the total status result is OK.

y

The status result will be kept until the next status result output. However, the output function turns OFF
when the program number is switched or external master image is registered.

y

The ON status of each output is as follows.
When Output Settings (Page 6-27) are [N.O.] : Status with NPN or PNP open collector ON.
When Output Settings (Page 6-27) are [N.C.] : Status with NPN or PNP open collector OFF.

Importing the Status Output

7