beautypg.com

KEYENCE IV Series User Manual

Page 279

background image

A-23

- IV Series User's Manual (Monitor) -

A

Error Messages

PWR/ERR

indicator

status

Cause

Remedy

Red

Blink

The external master image

registration error (with

registered master image)

occurred. The following

errors occurred even though

the image was updated and

registered as a master image.

y

For the new master image,

the outline cannot be

extracted with the outline

tool.

y

For the new master image,

the area cannot be extracted

with the color area/area tool.

y

An external master image registration error can be

fixed using one of the following procedures.

y

Successful next external master image registration

y

Clearing the Error input

y

Switching the program number

y

Proceeding to the settings screen of the sensor

y

Checking that the image to be registered and the

detection tools/position adjustment settings are

applicable.

An FTP error occurred. The

following errors occurred.

y

Connection with the FTP

server failed.

y

Tranfer to the transfer

destination folder failed.

y

The transfer speed could

not catch up the sensor

processing speed.

An FTP error can be fixed using one of the following

procedures.

y

Click the [OK] button on the Error screen.

y

Clear Error input.

y

Resolve the causes of transfer failure.

OFF

y

Power is not supplied to this

device.

y

During focusing position

adjustment.

(Manual focus type only)

y

Connect the power cable correctly.

y

Use a power source of the correct rating.

y

Complete the focusing position adjustment.

Errors in a state that the PWR/ERR indicator light lights in red or blinks in red turn the error output ON.

“Cables” (Page 2-12)

“4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60)