A-23
- IV Series User's Manual (Monitor) -
A
Error Messages
PWR/ERR
indicator
status
Cause
Remedy
Red
Blink
The external master image
registration error (with
registered master image)
occurred. The following
errors occurred even though
the image was updated and
registered as a master image.
y
For the new master image,
the outline cannot be
extracted with the outline
tool.
y
For the new master image,
the area cannot be extracted
with the color area/area tool.
y
An external master image registration error can be
fixed using one of the following procedures.
y
Successful next external master image registration
y
Clearing the Error input
y
Switching the program number
y
Proceeding to the settings screen of the sensor
y
Checking that the image to be registered and the
detection tools/position adjustment settings are
applicable.
An FTP error occurred. The
following errors occurred.
y
Connection with the FTP
server failed.
y
Tranfer to the transfer
destination folder failed.
y
The transfer speed could
not catch up the sensor
processing speed.
An FTP error can be fixed using one of the following
procedures.
y
Click the [OK] button on the Error screen.
y
Clear Error input.
y
Resolve the causes of transfer failure.
OFF
y
Power is not supplied to this
device.
y
During focusing position
adjustment.
(Manual focus type only)
y
Connect the power cable correctly.
y
Use a power source of the correct rating.
y
Complete the focusing position adjustment.
Errors in a state that the PWR/ERR indicator light lights in red or blinks in red turn the error output ON.
“4. Output Assignment (Setting Details of Outputting to Output Line)” (Page 4-60)