KEYENCE IV Series User Manual
Page 132
4-64
- IV Series User's Manual (Monitor) -
z
z
Logic : OR
Image of logic output when the Logic
is [OR]
Tool A
Logic 1 to 4
Tool B
Tool C
(Inverse)
Tool A
Tool B
Tool C
Logic
OK
OK
OK
OK
NG
OK
OK
OK
OK
NG
OK
OK
NG
NG
OK
NG
OK
OK
NG
OK
NG
OK
NG
OK
OK
NG
NG
OK
NG
NG
NG
OK
y
Select either [Unused]/[Used]/[Used
(Inverse)] for each item (Position Adjustment/
Tool 01 to Tool 16/Logic 1 to Logic 4).
y
When the status results of the [Used] items
were OK, the status output function for items
in the logic turns ON.
y
When the status results of the [Used
(Inverse)] items were NG, the status output
function for items in the logic turns ON.
y
To define a logic which has been set to
another logic, use the logic number which
is greater than the logic number which has
been set.
For example, use either of Logic 2 to Logic 4
in case of defining Logic 1 to another logic.
When the program number has been changed
and you went to [Run] from [Program] after
the power ON, the judgement is not done if no
trigger input. The judgement output of each
tool is OFF.
6
When the setting is completed, tap the
[OK] button.
The system returns to the Logic Settings screen.
7
Tap the [Close] button.
The system returns to the main screen for the
Outline tool settings.
Output Assignment
Extended functions
1. Image Optimization
2. Master Registration
3. Tool Settings
4. Output Assignment
4
Settings Navigator (Setting the Judgment Condition)