When the [External IN] is selected in the Program Switch Method
1
Start the run mode.
“Starting an Operation” (Page 5-2)
2
Select the program number to which the product to be judged is registered with the status
of the input line.
Change the input lines IN2 to IN6 which were assigned to bit0 to bit4 in the input settings (Page 6-26)
to the following statuses and maintain the settings. Start the run mode with the new program number.
Program
number
bit4
(MSB) bit3
bit2
bit1
bit0
(LSB)
Program
number
bit4
(MSB) bit3
bit2
bit1
bit0
(LSB)
PROG00 OFF OFF OFF OFF OFF
PROG16 ON
OFF OFF OFF OFF
PROG01 OFF OFF OFF OFF ON
PROG17 ON
OFF OFF OFF ON
PROG02 OFF OFF OFF ON
OFF
PROG18 ON
OFF OFF ON
OFF
PROG03 OFF OFF OFF ON
ON
PROG19 ON
OFF OFF ON
ON
PROG04 OFF OFF ON
OFF OFF
PROG20 ON
OFF ON
OFF OFF
PROG05 OFF OFF ON
OFF ON
PROG21 ON
OFF ON
OFF ON
PROG06 OFF OFF ON
ON
OFF
PROG22 ON
OFF ON
ON
OFF
PROG07 OFF OFF ON
ON
ON
PROG23 ON
OFF ON
ON
ON
PROG08 OFF ON
OFF OFF OFF
PROG24 ON
ON
OFF OFF OFF
PROG09 OFF ON
OFF OFF ON
PROG25 ON
ON
OFF OFF ON
PROG10 OFF ON
OFF ON
OFF
PROG26 ON
ON
OFF ON
OFF
PROG11 OFF ON
OFF ON
ON
PROG27 ON
ON
OFF ON
ON
PROG12 OFF ON
ON
OFF OFF
PROG28 ON
ON
ON
OFF OFF
PROG13 OFF ON
ON
OFF ON
PROG29 ON
ON
ON
OFF ON
PROG14 OFF ON
ON
ON
OFF
PROG30 ON
ON
ON
ON
OFF
PROG15 OFF ON
ON
ON
ON
PROG31 ON
ON
ON
ON
ON
y
When the polarity (Page 6-28) is [NPN] ON : the state shorted with 0 V line
OFF : Open
y
When the polarity (Page 6-28) is [PNP] ON : the state that voltage is applied
OFF : Open
For details of the controlling method and the timing chart, refer to “Changing Over” (Page 7-7).