5-28

- IV Series User's Manual (Monitor) -

Tool Auto Tuning (Automatically Adjusting the Judgment Condition)

Tool Auto Tuning by the registration

information file

When the registration information file (*.ivt), which
contains the Tool Auto Tuning images and criteria
information saved at the end of the previous Tool
Auto Tuning is used, the Tool Auto Tuning can be
performed skipping the OK/NG image registration
process.

y

You can additionally add a new image to the OK/
NG images registered with the previous Tool
Auto Tuning, and then perform Tool Auto Tuning.

y

You can readjust the tool settings after Tool Auto
Tuning, and then repeat Tool Auto Tuning by the
registered image.

Tuning based on the OK/NG images in the

registration information file

USB

memory

OK

NG

OK

OK

OK

OK

NG

Registered information file (*.ivt)

This is the function for the monitor operation software
version R1.10 or later. For the versions older than
R1.10, update the software to the latest version.

When you repeatedly perform Tool Auto Tuning

using the same registration information file, settings

might be changed each time being performed.

This phenomenon occurs since Tool Auto Tuning

consistently performs adjustment based on the latest

settings (settings changed immediately before).

1

Prepare the registration information file

(*.ivt).

A registration information file is saved at the
Tool Auto Tuning finish screen.
For the saving method, refer to the step 8 of

“Starting and finishing the Tool Auto Tuning”

(Page 5-16).

2

Display the Sensor Setup Menu screen.

“Displaying the Sensor Setup Menu Screen”

(Page 6-7)

3

Tap the [Tool Auto Tuning] button.

When the Tool Auto Tuning Guide screen opens,
tap the [Start] button.

4

If multiple tools are set in the program,

select the target tool for the Tool Auto

Tuning from the pull-down menu and tap

the [OK] button.

Select the tool

The Start Up Menu screen for the Tool Auto
Tuning opens.

5

Operating/Adjusting