Remedy when the Monitor cannot be Connected with the Sensor

Status

Remedy

The sensor was not found using the [Search

Sensor] button on the Sensor Connect

screen.

When the connection cannot be established by

searching for the sensor

y

Supply power to the sensor and the network equipment.

y

Correctly connect with the sensor and the network

equipment.

“Connecting via network” (Page 2-16)

y

Confirm that the IP address of the monitor does not

coincide with that of the sensor or another device. Also,

correctly set the subnet mask and the default gateway.

“Confirming/Setting the IP address of the monitor”

(Page A-36)

y

Change to direct connection and confirm that the IP

address of the sensor does not coincide with that of

the monitor or other devices. Also, reset (initialize) the

network setting for the sensor.

“When directly connecting with the sensor” (Page 6-46)

“Confirming/Setting the IP address of the sensor”

(Page A-37)

“Initializing the Network Settings (IP Reset Switch)”

(Page A-40)

y

The following conditions are required for a successful

sensor search.

y

The subnet masks of the sensor and monitor are matched.

y

The sensor network setting is not set or the IP address

is not duplicated.