Settings after initialization, Connecting method after initialization, For direct connection – KEYENCE IV Series User Manual
Page 296: For network connection, Initializing the network settings, For network connection ..................... a-40, Ip reset switch)
A-40
- IV Series User's Manual (Monitor) -
A
Initializing the Network Settings (IP Reset Switch)
The network settings such as the IP address can
be initialized to the factory default by means of the
IP reset switch of the sensor.
y
The IP reset switch is used when joining the
sensor used in another network to a new network,
or when trouble occurs during connection.
y
Do not initialize a correctly connected sensor.
The connection will be interrupted.
Settings after initialization
Setting Items
Settings after
initialization
Communication speed
100/10Mbps
Automatically switches
IP address setting
method
BOOTP
(Bootstrap Protocol)
IP Address
0.0.0.0
*1, *2
Subnet Mask
0.0.0.0
*2
Default Gateway
0.0.0.0
*2
*1 If the IP address is 0.0.0.0, only the BOOTP
client function can be used.
Do not assign an IP address from the BOOTP
server or DHCP server except the monitor to be
connected.
*2 In the Network Settings screen of the sensor,
[Empty] is displayed.
“Network Settings” (Page 6-31)
Connecting method after initialization
z
For direct connection
Connects automatically with BOOTP. There is
no need to set the IP address.
“When directly connecting with the sensor”
z
For network connection
Search for the sensor to be connected. Search
will be made for a sensor without IP address, set
the IP address by following the instructions on
the screen.
“When connecting with the sensor via a
Initializing the network settings
1
Remove the fixing screw of the front cover
indicated by the mark.
Remove only the fixing screw of the front
cover indicated by the mark. Do not remove
the front cover.
mark
Indicator light
2
Insert a long and thin pin (1 to 2 mm in
diameter) into the screw hole and press
the IP reset switch for about 3 seconds.
Long and
thin pin
The STATUS indicator light will blink twice
(orange) and then turn off.
The network setting is initialized.
3
Tighten the fixing screw of the front cover.
y
Tightening torque : 0.25 to 0.35 N·m
Initializing the Network Settings
(IP Reset Switch)