beautypg.com

KEYENCE IV Series User Manual

Page 212

background image

6-36

- IV Series User's Manual (Monitor) -

Setting the Extended Functions of the Sensor

„

z

File Name

Sets the file name of the transfer files.
When the [Edit] button is tapped, the “File Name”
screen opens.
Set an arbitrary file name and tap the [OK] button.

y

Default: None (black). Up to 16 characters

can be set.

y

For details of how to enter characters, refer

to “Inputting characters” (Page 3-16).

y

The transfer file naming rule is as follows.

xxxxxx_AAAAA_BB_CC.DDD

y

xxxxxx ...... The file name which has been

set (up to 16 characters)

y

AAAAA ..... A sequence number for each

FTP transfer (5 digits which

zero suppression is not used).

Promptly after startup, “00000”

is displayed.

y

BB ............ The program number (2 digits

which zero suppression is not

used)

y

CC ............ The total status result

(“OK” or “NG”)

y

DDD ......... The extension (“ivp” or “bmp”)

y

If there is a file with the same name at

the transfer destination, that file will be

overwritten. When you transfer image data

from multiple IV series, specify different

transfer destinations so that the image data

are not overwritten accidentally.

y

If the transfer destination folder is read only

or is opened, an FTP error will occur and the

image data transfer will fail.

„

z

Index Upper Limit

Sets the upper limit of the number of image
data which can be transferred to the transfer
destination folder.

When the file index quantity has reached the

index upper limit, as follows.

y

When the [Create Subfolder] is set to [ON],

the folder of the next sequence number is

created.

y

When the [Create Subfolder] is set to [OFF],

the file index quantity returns to “0”.

„

z

Create Subfolder

To create subfolders under the transfer
destination folder, select [ON].

y

The subfolder naming rule is as follows.

IVxxxxx

(xxxxx is a sequence number created

every time the sensor is restarted or the

FTP settings are changed.)

y

When subfolders were created, the folder

structure is as follows.

Root folder

Transfer destination folder

0000

0001

0002

Subfolder

When the file index quantity reaches the index

upper limit, the folder of the next sequence

number is created.

y

The default of subfolders is “IV00001”.

y

The upper limit is “IV99999”. When the upper

limit has been reached, the count continues

by returning to “IV00000”.

y

The subfolder name cannot be initialized.

y

The upper limit of the count number of folders

in the subfolder is “9999”. When the number

is over the upper limit, the transfer stops.

3

After the setting is completed, tap the [OK]

button.

The system returns to the main screen of the
FTP Settings.

6

Useful Features/V

arious Functions