KEYENCE IV Series User Manual
Page 212
6-36
- IV Series User's Manual (Monitor) -
Setting the Extended Functions of the Sensor
z
File Name
Sets the file name of the transfer files.
When the [Edit] button is tapped, the “File Name”
screen opens.
Set an arbitrary file name and tap the [OK] button.
y
Default: None (black). Up to 16 characters
can be set.
y
For details of how to enter characters, refer
to “Inputting characters” (Page 3-16).
y
The transfer file naming rule is as follows.
xxxxxx_AAAAA_BB_CC.DDD
y
xxxxxx ...... The file name which has been
set (up to 16 characters)
y
AAAAA ..... A sequence number for each
FTP transfer (5 digits which
zero suppression is not used).
Promptly after startup, “00000”
is displayed.
y
BB ............ The program number (2 digits
which zero suppression is not
used)
y
CC ............ The total status result
(“OK” or “NG”)
y
DDD ......... The extension (“ivp” or “bmp”)
y
If there is a file with the same name at
the transfer destination, that file will be
overwritten. When you transfer image data
from multiple IV series, specify different
transfer destinations so that the image data
are not overwritten accidentally.
y
If the transfer destination folder is read only
or is opened, an FTP error will occur and the
image data transfer will fail.
z
Index Upper Limit
Sets the upper limit of the number of image
data which can be transferred to the transfer
destination folder.
When the file index quantity has reached the
index upper limit, as follows.
y
When the [Create Subfolder] is set to [ON],
the folder of the next sequence number is
created.
y
When the [Create Subfolder] is set to [OFF],
the file index quantity returns to “0”.
z
Create Subfolder
To create subfolders under the transfer
destination folder, select [ON].
y
The subfolder naming rule is as follows.
IVxxxxx
(xxxxx is a sequence number created
every time the sensor is restarted or the
FTP settings are changed.)
y
When subfolders were created, the folder
structure is as follows.
Root folder
Transfer destination folder
0000
0001
0002
Subfolder
When the file index quantity reaches the index
upper limit, the folder of the next sequence
number is created.
y
The default of subfolders is “IV00001”.
y
The upper limit is “IV99999”. When the upper
limit has been reached, the count continues
by returning to “IV00000”.
y
The subfolder name cannot be initialized.
y
The upper limit of the count number of folders
in the subfolder is “9999”. When the number
is over the upper limit, the transfer stops.
3
After the setting is completed, tap the [OK]
button.
The system returns to the main screen of the
FTP Settings.
6
Useful Features/V
arious Functions