beautypg.com

Changing the timing of the status output, Cancelling one-shot output, Changing the timing of the status output -6 – KEYENCE IV Series User Manual

Page 236: Cancelling one-shot output -6

background image

7-6

- IV Series User's Manual (Monitor) -

Importing the Status Output

Changing the timing of the status output

The timing of status output can be selected from the [Latching] which links to judgment and [One-Shot]
which outputs for a certain time. For details on settings, refer to “Output Settings” (Page 6-27).

BUSY output

Status output

(Latching output)

Status output

(One-Shot output)

Status result of Trigger 1

Status result of Trigger 2

Previous status result

Status result of Trigger 1

Status result of Trigger 2

Delay time

Delay time

One-Shot ON Time

One-Shot ON Time

External trigger/Internal

trigger

Min 0.2 ms

ON

OFF

ON

OFF

ON

OFF

Trigger 1

Trigger 2

y

In case of [Latching], updates the output by linking with judgment.

y

In case of [One-Shot], outputs in a set amount of time after the set delay time is passed.

y

When the program number is switched or the external master image is registered, the status output turns
OFF before each process is completed.

Cancelling One-Shot output

To use the One-Shot output function, the following condition needs to be met.

Trigger input interval (Trigger interval) > One-Shot ON Time

If the above is not met, the following One-Shot output that occurs during the One-Shot outputting is
cancelled and is not output.

Trigger input interval

One-Shot ON Time

Judgment process

Internal process of Trigger

2

Internal process of Trigger

1

BUSY output

Status result of Trigger 1

Status result of Trigger 1 (internal)

Status result of Trigger 2 (internal)

One-Shot ON Time

Delay time

Delay time

Delay time

One-Shot ON Time

(1)

(2)

(3)

External trigger/Internal

trigger

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Trigger 1

Trigger 2

(1) This is an example of what happens when the trigger input interval is shorter than the One-Shot ON Time.
(2) To perform the One-Shot output and output the status result of Trigger 1, the previous One-Shot output

is completed, so that outputting can be performed normally.

(3) To perform One-Shot output and output the status result of Trigger 2, the One-Shot output of Trigger 1

is output. Therefore, the output status of Trigger 2 will be cancelled and it will not be output.

y

If the BUSY time is not constant, meet the following condition to use it. The system might be affected by
a fluctuating BUSY time.

BUSY time + Trigger input interval (Trigger interval) > BUSY time + One-Shot ON Time

7

Controlling with the Input/Output Line