Importing the individual status output of, Each detection tool / logic -5 – KEYENCE IV Series User Manual
Page 235
7-5
- IV Series User's Manual (Monitor) -
Importing the Status Output
Importing the individual status output of each detection tool / logic
The individual status result of the detection tool and position adjustment for the examined target can be checked.
Orange line: OUT 4
Assign "Logic 1"
Gray line: OUT 3
Assign "Tool 2"
White line: OUT 2
Assign "Tool 1"
Black line: OUT 1
Assign the BUSY output
Trigger input
Previous result
Status result of Tool 1
Previous result
Status result of Tool 2
Previous result
Status result of Logic 1
Processing time
Min 0.2 ms
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Trigger 1
y
The operation example when the output mode (Page 6-27) of status output is set to [Latching]. When the
output mode is set to [One-Shot], refer to “Changing the timing of the status output” (Page 7-6).
y
This is an example when the status results of Tool 1, Tool 2, and Logic 1 are to be checked individually.
y
The status output turns ON when the status result of each tool/logic was OK. Turns OFF when the result
was NG or --.
y
The ON status of each output is as follows.
When Output Settings (Page 6-27) are [N.O.] : Status with NPN or PNP open collector ON.
When Output Settings (Page 6-27) are [N.C.] : Status with NPN or PNP open collector OFF.
y
The status result will be kept until the next status result output. However, the output function turns OFF
when the program number is switched or external master image is registered.
7
Controlling with the Input/Output Line