Setting the trigger options, Settings for the trigger options, Setting the trigger options -8 – KEYENCE IV Series User Manual
Page 76: Settings for the trigger options -8
4-8
- IV Series User's Manual (Monitor) -
Setting the Trigger Options
A trigger in this manual indicates the timing to start imaging with the built-in camera of the sensor. In the
Trigger Options, set the timing to image a target within the field of view of this device. This device can
image a target at any timing, and can image continuously.
Settings for the Trigger Options
Items
Description
Setting range
Default
value
Trigger
(Trigger type)
Select the type of the timing to
start imaging.
y
Internal
Starts imaging continuously within
the time interval specified in the
trigger interval setting.
y
External
Starts imaging with the external
trigger synchronized with the
target's motion from a photoelectric
sensor or PLC installed outside.
The time (trigger delay) between
inputting the trigger until imaging
starts can be set.
Internal
Trigger interval
Set when the [Internal] is
selected in the trigger type
setting.
Set an interval (cycle) to
automatically start imaging.
1 to 10000 ms
50 ms
Trigger Delay
Set when the [External] is
selected in the trigger type
setting.
Used when the output timing
of the sensor for the trigger
occurrence and the imaging
timing of this device cannot be
synchronized.
This device starts imaging after
the time set in the trigger delay
of the trigger input passes.
0 to 1000 ms
0 ms
Trigger Options
Auto Brightness Adjustment Focus Adjustment Extended functions
1. Image Optimization
2. Master Registration
3. Tool Settings
4. Output Assignment
4