Displaying and outputting the status result – KEYENCE IV Series User Manual
Page 260
A-4
- IV Series User's Manual (Monitor) -
A
Status Table
Displaying and outputting the status result
Status
Judgment of each tool
Total Status
*2
Total Status
NG
Display
Output
Display
Output
Output
Judgment
Matching rate
*1
Waiting for a trigger
(Not judged)
*3
--
---
OFF
--
OFF
OFF
Judge is OK
OK
0 to 100
ON
*4
*5
Judge is NG
NG
0 to 100
OFF
Unable to judge
*6
--
---
OFF
*6
OFF
ON
*1 When the setting scale is changed by the Color Area/Area tool, 0 to 200/0 to 999 can be selected.
The cut-off process (Page A-5) may be performed for the outline tool and the position adjustment tool.
*2 The total status conditions can be selected from [All Tools OK], [Any Tool OK] and [Logic 1] to [Logic 4].
“Total Status Conditions” (Page 4-65)
*3 In this status, there is no trigger input after the power turned ON, after the program number has
changed, or after a shift from the setting mode to the run mode.
*4 When the total status result is OK, the total status output turns ON.
*5 When the total status result is NG, the total status NG output turns ON.
*6 The judgment of position adjustment tool cannot be determined if the judgment of each tool cannot be
determined at the time of using the position adjustment tool. For details, refer to “Displaying and
outputting the status result at the time of position adjustment” (Page A-4).
Displaying and outputting the status result at the time of position adjustment
Position
adjustment
result
Window
protrusion
*1
Display/output
Judgment of each tool
Total
Status
*2
Total Status
NG
Pos. Adj.
Outline Color Area/
Area
Succeeded
No
View judgment
OK
OK/NG
OK/NG
*3
Status output
ON
ON/OFF
ON/OFF
*4
View matching rate
0 to 100
0 to 100
0 to 100
*5
Yes
View judgment
OK
OK/NG
--
*6
*3
Status output
ON
ON/OFF
OFF
*4
View matching rate
0 to 100
0 to 100
*7
---
*6
Failed
View judgment
NG
--
--
NG
Status output
OFF
OFF
OFF
OFF
ON
View matching rate
0 to 100
---
---
*1 This is an operation for if the adjusted position of the tool window is protruded from the imaging area
(Page 4-17) at the time of position adjustment succeeded.
*2 The total status conditions can be selected from [All Tools OK], [Any Tool OK] and [Logic 1] to [Logic 4].
“Total Status Conditions” (Page 4-65)
*3 When the total status result is OK, the total status output turns ON.
*4 When the total status result is NG, the total status NG output turns ON.
*5 0 to 200/0 to 999 can be selected when the setting scale has been changed.
*6 For details of the target’s outline which is protruded from the search region, refer to “Matching rate
at the time of protrusion” (Page A-5)
*7 The judgment cannot be determined if the adjusted position of the tool window is protruded from the
imaging area.