6-42

- IV Series User's Manual (Monitor) -

Setting the Extended Functions of the Sensor

Program Switch Method

Sets the method for switching the program number.

“Changeover for a Target (Program Functions)”
(Page 6-8)

1

Tap the [Sensor Advanced] button in the

Sensor Setup Menu screen.

2

Tap the [Program] button and tap the

[Program Switch Method] button.

3

Set a program switch method.

y

Monitor/PC ........ The program number is

switched by the monitor or IV-
Navigator (IV-H1) operation.

y

External IN ....... The program number is

switched by the external input.

To use the [External IN], any of the program

bit0 to bit4 must be assigned to any of the IN2

to IN6 in the input settings.

“Input Settings” (Page 6-26)

4

After the setting is completed, tap the [OK]

button.

Auto Focus Adjustment Position

(auto focus type only)

Sets whether or not to make the adjusting position
for the auto focus common to all programs.

1

Tap the [Sensor Advanced] button in the

Sensor Setup Menu screen.

2

Tap the [Program] button and tap the [Auto

Focus Adj Pos] button.

3

Set an auto focus adjustment position.

z

z

Common

Sets the focus adjustment position common to
all programs. Select this when the focus position
of the target registered in each program is
common. The program can be quickly switched
because re-adjustment of the focusing position
will not be performed when the program number
is switched.

z

z

Individual

Sets the focus adjustment position in each
program. Select this when the focus position
is different for each target registered in each
program. Re-adjusts the focusing position when
the program number is switched. Switching
programs takes longer in this option due to the
time needed to adjust the focusing position.

6

Useful Features/V