beautypg.com

Troubleshooting – KEYENCE IV Series User Manual

Page 275

background image

A-19

- IV Series User's Manual (Monitor) -

A

Troubleshooting

Symptom

Check point

Remedy

Reference

page

The PWR/ERR indicator light

of the sensor or the PWR

indicator light of the monitor

is lighting or blinking in red.

An error occurred. Check the

errors from lighting or blinking

in red.

Refer to "Error Message".

A-22

An error message is

displayed on the monitor.

Check the details of the error

message.

Refer to "Error Message".

A-22

The power is not supplied to

the sensor or monitor does

not turn on.

Is the power cable correctly

connected?

Connect the power cable

correctly.

2-12

Is the voltage or capacity of

the power source meet the

specification?

Use a power source of the

correct rating.

8-2

An image is not displayed on

the monitor, or the image is

abnormal.

Is the installed distance of the

target correct?

Place a target at the correct

installed distance. The

installed distance depends on

the sensor type.

2-2

Is the sensor view correct?

Place the sensor in such a way

that the sensor view matches

the target size.

2-2

Is the focus adjustment correct? Adjust the focusing position

(focus) of the sensor.

4-12

Is the brightness adjustment

correct?

Adjust the brightness of the

sensor.

4-11

Is the target or the sensor

vibrating?

Devise anti-vibration measures

etc.

-

Does the ambient light affect

the image?

Use brightness correction.

4-26

Place the douser to prevent

the incident of ambient light.

-

Is the front cover dirty or

damaged?

Clean the front cover. Replace

it with the spare front cover

(OP-87461).

A-41

Is the function of Update Image

in the RUN mode set to [OFF]?

Set the function of Update

Image in the RUN mode to [ON].

6-49

The image or the status

result is not updated.

Is the system in the setting

mode?

y

Start the run mode

y

Turn on the power of the

sensor again.

5-2

Is the trigger correctly input?

If a target is to be imaged

using an external trigger, input

the external trigger. When the

NPN is selected in the Polarity,

the circuit becomes a non-

voltage input circuit. When

PNP is selected in the Polarity,

the circuit becomes a voltage

input circuit. Check the cables.

2-12

All or part of the settings

necessary for running have not

been completed.

Complete the settings in

Settings Navigator.

4-1

Troubleshooting