Data Type
Column Name
Not standard; indicates whether the power supply is present
in the chassis
NVARCHAR(32)
dc_PowerSupplyPresent
The status of the power supply (noError (1), generalFailure
(2), bistFailure 32), fanFailure (4), tempFailure (5),
interlockOpen (6), epromFailed (7), vrefFailed (8),
dacFailed (9), ramTestFailed (10), voltageChannelFailed
(11), orringdiodeFailed (12), brownOut (13),
giveupOnStartup (14), nvramInvalid (15),
calibrationTableInvalid (16))
NVARCHAR(64)
dc_PowerSupplyStatus
Not standard; the redundancy state of the power supply
NVARCHAR(32)
dc_PowerSupplyState
Not standard; capacity and or output power of the power
supply in watts
INT
dc_CurrentOutputInfo
OtherIdentifyingInfo captures additional data, beyond
DeviceID information, that could be used to identify a
LogicalDevice
NVARCHAR(256)
OtherIdentifyingInfo
Indication of the type the power supply device including:
"0" = Unknown
"1" = Other
"2" = Compute Cabinet Bulk Power Supply
"3" = Compute Cabinet System Backplane Power Supply
"4" = Compute Cabinet I/O chassis enclosure Power
Supply
"5" = Compute Cabinet AC Input Line
"6" = I/O Expansion Cabinet Bulk Power Supply
"7" = I/O Expansion Cabinet System Backplane Power
Supply
"8" = I/O Expansion Cabinet I/O chassis enclosure Power
Supply
"9" = I/O Expansion Cabinet AC Input Line
SMALLINT
Type
Position is a free-form string indicating the placement of a
PhysicalElement. It can specify slot information on a
HostingBoard, mounting site in a Cabinet, or latitude and
longitude information, for example, from a GPS. It is part
of the key of the Location object.
NVARCHAR(64)
Location
Position is a free-form string indicating the placement of a
PhysicalElement. It can specify slot information on a
HostingBoard, mounting site in a Cabinet, or latitude and
longitude information, for example, from a GPS. It is part
of the key of the Location object.
NVARCHAR(64)
PhysicalPosition
The Caption value can be one of the following, depending
on the device type:
• Compute Cabinet Bulk Power Supply
• Compute Cabinet Backplane Power Supply
• Compute Cabinet I/O Chassis Enclosure Power Supply
• Compute Cabinet AC Input Line
• I/O Expansion Cabinet Bulk Power Supply
• I/O Expansion Cabinet Backplane Power Supply
• I/O Expansion Cabinet I/O Chassis Enclosure Power
Supply
• I/O Expansion Cabinet AC Input Line
• Cooling Device Slot
• Power Device Slot
Note: This property may not be available when the cell is
powered off.
NVARCHAR(64)
Caption
Displays manufacturer Hewlett-Packard
NVARCHAR(64)
Manufacturer