Installing the Cabinet system

For point-to-point 100BaseT connectivity, go to

step 6

.

For 100BaseT or 100BaseF connectivity over a distributed data
campus network, go to

step 7

.

4

For fiber connectivity, connect the main cabinet to the fiber expansion
cabinets. Refer to

"Fiber expansion daughterboards and cables"

(page 166)

and

"Installing Fiber Receiver cards on expansion

cabinets and chassis" (page 174)

.

5

For point-to-point 100BaseF connectivity, connect the main cabinet
to the IP expansion cabinets using the A0346816 5-meter fiber cable
with fiber couplers.

Use the supplied A0346816 ST fiber couplers to connect the ST
ends on the A0817052 fiber cables coming from the main and
IP expansion cabinets. Use one coupler to connect Tx to Rx
and another coupler to connect Rx to Tx. Use a push and twist
motion to secure the couplers to the cable ends.

Connect the fiber cable from the main cabinet to the fiber cable
from the IP expansion cabinet.

Note: The cable end labelled "A" is for Transmit (Tx) and the
cable end labelled "B" is for Receive (Rx). Refer to

Figure 24

"Cable ends and fiber coupler for 100BaseF connectivity" (page
79)

.

6

For point-to-point 100BaseT connectivity, connect the main cabinet
to the IP expansion cabinet using the NTTK34 crossover cable.

Use the NTTK34 2 m (6 ft 6 in.) UTP CAT 5 RJ–45 crossover
cable and NTDK8305 2 m (6 ft 6 in.) STP CAT 5 extension
cable to connect the main and IP expansion cabinets using the
100BaseT IP daughterboards.

Connect the NTDK8305 extension cable ends from the main and
IP expansion cabinets to the crossover cable.

7

To connect the main and IP expansion cabinets over a distributed
data campus network, do the following:

Use the A0817052 5 m (16 ft 4 in.) fiber cable with MT-RJ to
ST connectors to connect the main and IP expansion cabinets
using the 100BaseF IP daughterboards. The two A0817052 fiber
cables are usually connected to the enterprise IP network.

Use the NTDK8305 2 m (6 ft 6 in.) STP CAT 5 extension cable to
connect the main and IP expansion cabinets using 100BaseT IP
daughterboards. A customer-supplied straight-through cable is
used in place of the NTTK34 2 m (6 ft 6 in.) crossover cable.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008

Copyright © 2008, Nortel Networks

.