Terminal block requirements – Nortel Networks 1000M User Manual
Page 214

214
Installing and connecting cross-connect terminals
Terminal block requirements
This section describes the respective terminal block requirements for the
Cabinet system and the Chassis system.
Terminal block requirements for the Cabinet system
The cross-connect terminal requires sufficient connecting blocks to
terminate the following:
•
up to ten 25-pair cables from each cabinet
— Each slot that is equipped with a trunk or line circuit card requires
a cable.
–
The connectors J1 through J10 correspond to slot numbers 1
through 10 in the main cabinet.
–
Connectors J1 through J10 correspond to slot numbers 11
through 20 in the first expansion cabinet.
–
Connectors J1 through J10 correspond to slot numbers 21
through 30 in the second expansion cabinet.
–
Connectors J1 through J10 correspond to slot numbers 31
through 40 in the third expansion cabinet.
–
Connectors J1 through J10 correspond to slot numbers 41
through 50 in the fourth expansion cabinet.
–
Allow for additional cables at the cross-connect terminal if any of
the ten slots in each cabinet are initially left vacant.
— If the NTAK19 SDI cable is not used with the NTAK02 card, then a
25-pair cable is required.
•
nine conductors comprising the AUX cable from each cabinet
•
one 25-pair cable from each QUA6 PFTU
•
wiring from telephones and trunks
Terminal block requirements for the Chassis system
The cross-connect terminal requires enough connecting blocks to terminate
the following wires:
•
for the NTAK09 circuit card, use the NTBK04 cable
•
for the NTAK10, NTAK79, and NTBK50 circuit cards, use the NTBK05
cable
•
up to five 25-pair cables from each chassis
— Each slot that is equipped with a trunk or line circuit card requires
a cable.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310
01.04
Standard
Release 5.0
13 May 2008
Copyright © 2008, Nortel Networks
.