Figure 89 cable routing guide under main cabinet – Nortel Networks 1000M User Manual

Page 187

background image

Installing the NTDK20 SSC card on the Main Cabinet or Chassis

187

Figure 89
Cable Routing Guide under main cabinet

Procedure 28

Installing the 100BaseF IP expansion daughterboard on the SSC card on
the Main Cabinet or Chassis

Step

Action

1

Put on the antistatic wrist strap.

2

Place the SSC card on a clean, flat, ESD-dissipated surface.

3

Remove the protective plugs from the connectors on the
daughterboard.

4

Insert the A0817052 MT-RJ to ST cable end into the daughterboard
connector. See

Figure 91 "Cable ends and fiber coupler" (page

189)

for identification of cable ends.

Repeat

step 4

if a second fiber connection is required.

Note 1: With new connectors, push very firmly until a definite
"click" is heard. Pull gently on the connection to make sure it
is secure.

Nortel Communication Server 1000

Communication Server 1000M and Meridian 1 Small System Installation and Commissioning

NN43011-310

01.04

Standard

Release 5.0

13 May 2008