Figure 89 cable routing guide under main cabinet – Nortel Networks 1000M User Manual
Page 187
Installing the NTDK20 SSC card on the Main Cabinet or Chassis
187
Figure 89
Cable Routing Guide under main cabinet
Procedure 28
Installing the 100BaseF IP expansion daughterboard on the SSC card on
the Main Cabinet or Chassis
Step
Action
1
Put on the antistatic wrist strap.
2
Place the SSC card on a clean, flat, ESD-dissipated surface.
3
Remove the protective plugs from the connectors on the
daughterboard.
4
Insert the A0817052 MT-RJ to ST cable end into the daughterboard
connector. See
Figure 91 "Cable ends and fiber coupler" (page
for identification of cable ends.
Repeat
if a second fiber connection is required.
Note 1: With new connectors, push very firmly until a definite
"click" is heard. Pull gently on the connection to make sure it
is secure.