Procedure 31 installing the universal trunk card – Nortel Networks 1000M User Manual
Page 199

Circuit cards
199
You can install this line card in:
•
slots 1 through 10 in the main cabinet or slots 11 through 50 in the
expansion cabinets
•
slots 1 through 3 in the chassis, slots 7 through 10 in the chassis
expander, or in the expansion chassis
Procedure 30
Installing the Universal Trunk card
Step
Action
1
Set the jumpers for the NT8D14 Universal Trunk circuit card
according to
Table 26 "NT8D14 Universal Trunk: modes and option
Table 26
NT8D14 Universal Trunk: modes and option settings
Modes
Location
Jumper
strap
Central (CO)
J1, J2
OFF
2-way TIE trunk (loop Dial Repeat)
J1, J2
OFF
2-way TIE trunk (Outgoing
Incoming Dial)
J1, J2
OFF
Recorded Announcement (RAN)
J1, J2
OFF
Paging trunk
J1, J2
OFF
Japan CO/DID operation
J1, J2
OFF
DID operation
Loop length>2000 ohms
J1, J2
ON
DID operation
Loop length <2000 ohms
J1, J2
OFF
OFF indicates no strap present. J1 and J2 locations apply to all 8 trunks.
2
Insert the card in its assigned slot.
—End—
NT8D15 E and M Trunk card
The E and M trunk card provides four trunks which can function as 2W
E&M, 4W E&M, and Paging.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310
01.04
Standard
Release 5.0
13 May 2008
Copyright © 2008, Nortel Networks
.