Chassis system equipment
The chassis supports the following:
•
NTDK20 Small System Controller (SSC) card installed in slot 0
•
any IPE or CE card in slots 1, 2, and 3
•
a dedicated 48-port Digital Line Card (NTDK16) in slot 4
The chassis expander supports the following:
•
Meridian Mail in slot 10 only.
•
With Meridian Mail in slot 10, you can insert any IPE card in slots 7,
8, and 9.
Chassis installation options
You can install the chassis and chassis expander in the following positions:
•
in a rack/equipment cabinet
•
on a wall
— vertically on a wall
— horizontally on a wall
The following chassis installation kits are available:
•
NTTK08AA: for vertical, wall installation
•
NTTK09AA: for rack/cabinet installation
•
NTTK11AA: for horizontal, wall installation
Cable connectors
25-pair cables connect cards to the cross-connect terminal. Connectors for
these cables are on the back of the chassis and the chassis expander. See
Figure 16 "25-pair cable connectors on the back of the chassis" (page 41)
.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Installation and Commissioning
NN43011-310